SKC 224-PCXR8 Air Sampling Pump

skc_pcxr4
$25.00 each
Rental Term

Brand: SKCSKC
$25.00
$95.00
$285.00

Operating Range

  • 1000 to 5000 ml/min (UL Listed model)
  • 1000 to 3000 ml/min (MSHA-approved model)
  • (5 to 500 ml/min requires the 224-26 Series Adjustable Low Flow Holder)

Weight

  • 34 oz (964 gm)

Dimensions

  • 5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm)

Compensation Range

  • 1000 to 2500 ml/min at 40 inches water back pressure
  • 3000 ml/min at 35 inches water back pressure
  • 4000 ml/min at 20 inches water back pressure
  • 5000 ml/min at 10 inches water back pressure

Flow Control

  • Holds constant flow to ± 5% of set-point

Run Time

  • Battery: 8 Hours minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used.
  • Run Time: Mains Adapter: 9999 minutes (6.8 days). Pump will shut off as run time cannot exceed timer display (see Timer Display Range below)

Timer Display Range

  • 1 to 9999 minutes (6.8 days). Pump will shut off at 9999 minutes. To reset, restart the pump

Flow Indicator

  • Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min
  • Charging Time

    • 6 to 8.5 hrs with PowerFlex charger (varies with capacity and level of charge)

    Power Supply

      6.0 V plug-in NiCad battery pack, rechargeable, 2.0-Ah capacity

    Intrinsic Safety

    • UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C
      ATEX-approved model is available

    Temperature

    • Operating Temperature: 32 to 113 F (0 to 45 C)
    • Storage Temperature: -40 to 113 F (-40 to 45 C)
    • Charging Temperature: 50 to 113 F (10 to 45 C)

    Operating Humidity

    • 0 to 95% Relative

    Flow and Low Battery Fault

    • Fault shutdown on excessive back pressure or low battery with LCD indicator and time display retention

    Battery Test

    • LCD indicator verifies battery condition prior to sampling

    Time Display

    • LCD indicator displays sampler run time in minutes

    Delay On

    • Allows user to select minutes to delay start of test up to 9999 minutes (6.8 days)

    Timed Shutdown

    • Allows user to select minutes of operation before automatic shutdown. Timed shutdown maximum is 9999 minutes (6.8 days)

    Timing Accuracy

    • ± 0.05% (± 45 sec/day)

    Sampling

    • Intermittent Sampling: Programmable to allow user to extend short-term samples over an extended period of time to meet time weighted average (TWA) requirements with a reduced number of samples. Elapsed time maximum is 9999 minutes (6.8 days), at which time the sample pump shuts down.
    • Sampling Pause: Allows user to temporarily halt sampling without loss of timing data. Restart does not require resetting time.
    • Multiple-tube Sampling: Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable low flow holder accessory

    RFI/EMI Shielding

    • Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1
    • Frequency range of the radiated susceptibility test was 27 to 1000 MHz
    • CE marked
    Mp>Additional Specifications

    • Built-in fluid/particulate trap
    • External see-through filter housing
    • Tamper-resistant control cover
    • Tamper-resistant compensation adjustments
    • Built-in accessory mount
    • Stainless steel belt clip
    • External exhaust port
    • All non-plastic parts made of corrosion-resistant materials
    • RFI and EMI-shielded case